APC ACRD501 Server cabinet/enclosure InRow Cooling

APC
In stock
Part Code :
ACRD501


Close-coupled, air, water, and glycol cooling for closets, server rooms, and data centers.

APC ACRD501 InRow Rd Air-cooled Server Aisle Row Air Airflow Cooling System

  • Availability

          Predictable cooling 

          Placing the unit in the row of racks moves the source of cooling closer to the heat load. This eliminates air mixing and provides a predictable cooling architecture.

           Rack Inlet Temperature Control 

           Reduces the risk of hot spots at the rack level

           Active response controls

           Monitors and actively adjusts cooling capacity to ensure proper server inlet temperatures.Through the microprocessor controller, visibility into the operation and health of the unit is provided.

  • Total Cost of Ownership

           Variable speed fans 

           Variable speed fans reduce energy consumption during off-peak cooling periods.

            In-Row architecture 

            Captures hot exhaust air directly from the IT equipment, thereby increasing the unit's sensible cooling capacity over traditional cooling architectures.

  •  Agility

            Modular design 

            Modular design provides scalable solutions to add cooling as demand increases.

             Scaleable densities

            Allows for higher densities to be achieved by integrating containment with room, row and rack cooling system architectures.

  •   Serviceability

             Easy service access 

             Allows for all serviceable components to be replaced/maintained by easily accessible panels/doors.

             Manageability

             Microprocessor controller  Utilizes intelligent, active response control, and real-time monitoring. The system is controlled by a microprocessor providing high level control functionality and human interface via a four line, eighty character, alphanumeric display.

             Building management system integration 

             Send alarms and data points allowing you to manage critical building infrastructure from a single system.

             Real-Time Capacity Monitoring 

             Real-time display of current and available cooling.

General

Compressor Type Reciprocating
Air Discharge Patterns Horizontal
Intake Air Rear Return
Air Flow 2170.96 lps
Condensate Pump Capacity 0.008 lps

Input

Nominal Input Voltage 460 (3PH)

Part Code:

ACRD501

You're reviewing:APC ACRD501 Server cabinet/enclosure InRow Cooling